Shandong IRO H2o Treatment Co., Ltd can be a international leader in the creation of drinking water therapy chemical compounds. IRO focuses on these products that water treatment method experts employ including biocides, polymers, other and phosphonates related chemistries.

Which chemical compounds are required for main air conditioner normal water treatment?

Such as corrosion and scaleinhibitors and dispersants, and fungicides, the fouling ions in water are stabilized in water, by adding water stabilizers. The key would be to support magnesium and calcium ions by complexation, adsorption and chelation and dispersion. The ground is dissolved in h2o by chelate complexation, and contains a good dispersing effect on colloids for webpage example iron oxide and silica. Because the corrosion inhibitor forms a protective motion picture which happens to be insoluble in water or inadequately soluble in h2o on top from the steel, the deterioration impulse is suppressed by working against the hydration impulse or maybe the dissolved air reaction of your metallic ions. The particular chemical range inhibition and corrosion inhibition impact is unveiled below. This process happens to be the most typical technique for key air cooling water treatment method. It is also by far the most commonly used and a lot adult method in manufacturing h2o treatment method. Practice has proved that this economical and effective method.

In addition aluminum pre-shooting broker, bactericidal algaecide, gradual-launch anti--scaling professional can fundamentally be used, it is recommended to utilize the automatic dosing process, then regularly thoroughly clean the liquid, alright. Main ac units usually use carbon dioxide metallic piping. The interior wall from the water pipe will likely be corroded, and also the normal water will breed of dog bacteria, as well as the biofilm will follow the internal wall from the temperature exchanger coil from the refrigerator and air conditioner, that can really impact the warmth trade productivity. A further professional would be to hold back the appearance of the aforementioned two circumstances.

Put rust inhibitor and bactericide on the chilled drinking water, put rust inhibitor to the boiling water, if the warm water is running above 80 degrees, you need to include range inhibitor (if the hydration in the warm water product is delicate h2o) No will need). Add more rust inhibitor and bactericide for the cooling down water.

Before the pipeline system is put into operation, it is necessary to flush the pipeline to the turbidity level and add the pre-filming agent. A passivation movie is actually created about the inner wall of your water pipe. To slow the rust from the interior wall surface of the pipe.